FAA L830 Transformer Qualification
|
4.2.3 Insulation Resistance (confirmation)
|
All measured leakage currents were at least two orders of magnitude less than the requirement as shown in the following table:
|
Coil |
DC Test
Voltage |
Actual
Measurement |
Specification |
Secondary |
5,000 |
< 0.1 µA* |
< 17 µA* |
Primary |
15,000 |
< 0.1 µA* |
< 20 µA* |
* For individual measurements, see Test Report, page 7, 8, and 9.
|
|
|
|
|
|
|